Does autofluorescence imaging videoendoscopy system improve the colonoscopic polyp detection rate?--a pilot study.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 18647285.
- Also identified by DOI 10.1111/j.1572-0241.2008.01931.x.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Colonoscopy is considered the gold standard for the detection of colorectal polyps; however, polyps can be missed with conventional white light (WL) colonoscopy. The aim of this pilot study was to evaluate whether a newly developed autofluorescence imaging (AFI) system can detect more colorectal polyps than WL. A modified back-to-back colonoscopy using AFI and WL was conducted for 167 patients in the right-sided colon including cecum, ascending and transverse colon by a single experienced colonoscopist. The patient was randomized to undergo the first colonoscopy with either AFI or WL (group A: AFI-WL, group B: WL-AFI). The time needed for both insertion and examination for withdrawal and all lesions detected in the right-sided colon were recorded. Eighty-three patients were randomized to group A and 84 to group B. The total number of polyps detected by AFI and WL colonoscopy was 100 and 73, respectively. The miss rate for all polyps with AFI (30%) was significantly less than that with WL (49%) (P= 0.01). AFI detects more polyps in the right-sided colon compared to WL colonoscopy.
Medical subject headings
- Colonic Polyps
- Colonoscopy
- Fluorescence
- Video Recording