Transient unilateral hyperlucent lung due to mucus plugs.

Bolliger, C T; Perruchoud, A P · Intensive Care Med · 1991

case_report · Level V

Where this comes from

Abstract

A 63-year-old patient with a tracheostomy presented with a transient unilateral hyperlucent lung and absent breath sounds over the left lower lobe. A tracheobronchial cast and an additional floating mucus plug in the left lower lobe bronchus were retrieved with fiberbronchoscopy. Subsequently normalisation of ventilation and radiological appearance of the left lung occurred.