In vivo evaluation of injectable thermosensitive polymer with time-dependent LCST.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 18671258.
- Also identified by DOI 10.1002/jbm.a.32179 and PMC identifier 2892920.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The focus of this study was to examine the biocompatibility, time-dependent LCST, and bioerodable properties of a copolymer system composed of NIPAAm, dimethyl-gamma-butyrolactone (DMBL), and acrylic acid (AAc). Sprague Dawley rats were subcutaneously injected with 25 wt % solutions of poly(NIPAAm-co-DMBL-co-AAc). At predetermined times, animals were sacrificed and polymer implants were recovered for characterization via 1H-NMR. In addition, polymer-contacting tissue sections were harvested and processed for histology. The biocompatibility of the implants was assessed by counting the number of fibroblasts and leukocytes present at the tissue-implant interface. The LCST data obtained from the in vivo implants was shown to agree with that of in vitro findings. Implant mass was shown to decrease after 4 days, indicating accelerated diffusion rates with increased implant swelling, hydrolytic degradation was confirmed with 1H-NMR measurements. The cellular presence at the copolymer implant-tissue interface was shown to return to that of normal tissue 30 days postimplantation, which suggests a normal wound healing response.
Medical subject headings
- Biocompatible Materials
- Implants, Experimental
- Polymers