Stabilization of microvascular pedicles in intricate locations using fibrin glue.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 18683869.
- Also identified by DOI 10.1002/micr.20536.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In reconstructive microsurgery, it is occasionally advantageous to use long recipient or donor vessels for optimal flap inset. These long vessels are prone to kinking or torsion along their longitudinal axis from vessel distension during blood inflow and rising blood pressure. More often than arteries, the veins can also be compressed by overlying tissue sutured under tension or by developing edema. Reanastomosis can no longer be feasible or desirable for several reasons, and the elongated vessels may have to be shifted to a curved course. To avoid detrimental kinking or torsion, fibrin glue can be administered along this new vessel course in order to ensure stabilization. In 20 such cases, we successfully avoided complications when the danger of kinking, torsion, or vein compression was evident after successful anastomosis. On the basis of this experience, we recommend the use of fibrin glue in microsurgical procedures, especially for vessels in intricate geometrical locations.
Medical subject headings
- Fibrin Tissue Adhesive
- Microsurgery
- Plastic Surgery Procedures
- Surgical Flaps
- Tissue Adhesives