Adaptive support ventilation with percutaneous dilatational tracheotomy: a clinical study.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 18713909.
- Also identified by DOI 10.1213/ane.0b013e31817f0e06.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We determined the need for changes in minute ventilation with adaptive support ventilation after percutaneous dilatational tracheotomy under endoscopic guidance in 34 intensive care unit patients. During the procedure, minute ventilation was not changed; only maximum pressure limits were adjusted, if necessary. After insertion of the tracheotomy, cannula minute ventilation was adjusted only if Paco(2)-values changed >or=0.5 kPa from baseline. In 74% of patients, adaptive support ventilation was unable to maintain minute ventilation during the use of the endoscope, mandating pressure limitation adjustments. In a minority of patients (26%), minute ventilation had to be adjusted to achieve similar Paco(2) values.
Medical subject headings
- Intubation, Intratracheal
- Respiration, Artificial
- Tracheotomy