Reliability of non-imaging-guided glenohumeral joint injection through rotator interval approach in patients undergoing diagnostic MR arthrography.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 18716085.
- Also identified by DOI 10.2214/AJR.07.3468.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of our study is to review the accuracy of our method of non-imaging-guided anterior glenohumeral gadolinium contrast injection targeting the rotator interval in 100 consecutive patients. One hundred consecutive community-referred patients at our MRI facility underwent non-imaging-guided glenohumeral contrast injection targeting the rotator interval, with no patients excluded on the basis of expected diagnosis. The studies were then retrospectively reviewed for accuracy of injection based on patient factors and diagnosis. This method was 99% accurate in our study, regardless of diagnosis. The relative ease, efficiency, reproducibility, and accuracy of this method of non-imaging-guided anterior glenohumeral injection make it the method of choice at our institution, and we believe this technique merits consideration for more widespread utilization.
Medical subject headings
- Arthrography
- Gadolinium DTPA
- Magnetic Resonance Imaging
- Shoulder Joint