Fractures of the distal tibia treated with polyaxial locking plating.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 18719970.
- Also identified by DOI 10.1007/s11999-008-0459-1 and PMC identifier 2635458.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial infections and evidence of delayed wound healing. Using the American Orthopaedic Foot and Ankle Society ankle score, the average functional score was 87.3 points (of 100 total possible points). Our results show the polyaxial locking plates, which offer more fixation versatility, may be a reasonable treatment option for distal tibia fractures with very short metaphyseal segments.
Medical subject headings
- Bone Plates
- Fracture Fixation, Internal
- Tibial Fractures
Anatomy
- ankle
- tibia