A novel technique of supra-annular mitral valve replacement.

Sung, Si Chan; Chang, Yun Hee; Lee, Hyoung Doo; Woo, Jong Soo · Ann Thorac Surg · 2008

case_report · Level V

Where this comes from

Abstract

We describe a new technique of mitral valve replacement in an 11.5-month-old, 5.5 kg baby whose native mitral annulus was only 14 mm. We successfully implanted a 16-mm mechanical valve in the supra-annular position by sewing it into a short polytetrafluoroethylene graft that was then sutured to the native annulus.