Arthrodesis with dual plates after failed total knee arthroplasty.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 1874763.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Eleven patients were treated by arthrodesis with dual compression plates after failed total knee arthroplasty. All patients had a solid fusion, at an average of 5.6 months after the operation. The complications included one femoral stress fracture and one persistent infection, both of which were treated successfully. Fixation with dual compression plates is a useful technique for the salvage of a failed total knee arthroplasty, even when the patient has an infection. Staggering of the plates may help to prevent late stress fractures.
Medical subject headings
- Arthrodesis
- Bone Plates
- Knee Joint
- Knee Prosthesis
Anatomy
- knee