Patient compliance with clinical follow-up after total joint arthroplasty.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 18762643.
- Also identified by DOI 10.2106/JBJS.G.00856.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Periodic clinical and radiographic evaluation is commonly recommended by orthopaedic surgeons to monitor patients following total joint arthroplasty, yet the compliance with and efficacy of patient follow-up protocols have not been well defined. The purpose of this study was to evaluate patient compliance with early clinical follow-up after total hip arthroplasty or total knee arthroplasty. We performed a retrospective review of clinical follow-up compliance for 776 patients who had undergone a total joint arthroplasty in the lower extremity. This cohort included 505 total hip arthroplasties (372 primary and 133 revision procedures) and 271 total knee arthroplasties (195 primary and seventy-six revision procedures). The patients were given one-time verbal instructions by the treating surgeon at the three-month postoperative visit to return for the one-year follow-up evaluation. At the one-year follow-up evaluation, those who returned were once again verbally instructed to return a year later. Demographic factors, functional hip and knee scores, and follow-up compliance at one and two years after surgery were assessed. Patient compliance with clinical follow-up after all arthroplasties was 61% at one year and 36% at two years. With use of a multivariate model for patients who had total hip arthroplasty, the analyses showed that a revision hip procedure (p = 0.006), younger patient age (p = 0.04), and a higher preoperative Harris hip score for gait (p = 0.04) were associated with follow-up compliance at two years. Of the factors analyzed for patients who had total knee arthroplasty, only nonwhite race (p = 0.03) was found to be a positive predictor of follow-up compliance at the two-year follow-up interval. Patient compliance with clinical follow-up after total joint arthroplasty in response to a verbal request made by the surgeon once at three months and once at one year postoperatively was poor in this series. These data indicate that this method (one-time verbal instruction) is insufficient to ensure compliance for follow-up after total joint arthroplasty.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Arthroplasty, Replacement, Knee
- Continuity of Patient Care
- Patient Compliance
Anatomy
- hip
- knee