Evaluation of a rapid enzyme immunoassay test for detection of group B Streptococcus.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 1876373.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to determine the reliability of the ICON immunoassay in detecting vaginal group B Streptococcus in pregnant women. Vaginal cultures were obtained at the time of sterile speculum examinations from 300 laboring women. The frequency of vaginal group B streptococcal colonization was 10%. A duplicate vaginal swab was used in the immunoassay, which required less than 10 minutes for completion. The immunoassay could reproducibly detect 3+ to 4+ growth (greater than 10(5) colony-forming units per milliliter of vaginal fluid), which was considered heavy colonization. The overall sensitivity, specificity, positive predictive value, and negative predictive value were 33, 95, 43, and 93%, respectively, compared with culture. For heavy colonization (3+ to 4+ growth), the sensitivity, specificity, positive predictive value, and negative predictive value were 100, 95, 32, and 100%, respectively. The immunoassay is a highly sensitive and specific test for detection of heavy vaginal colonization by group B streptococci in obstetric patients, but cultures are required to detect light group B streptococcal colonization.
Medical subject headings
- Immunoenzyme Techniques
- Pregnancy Complications, Infectious
- Streptococcal Infections
- Streptococcus agalactiae
- Vagina