Cyclic stress analysis of flexor tendon repair.

Pruitt, D L; Manske, P R; Fink, B · J Hand Surg Am · 1991

biomechanical · Level V

Where this comes from

Abstract

A method of evaluating flexor tendon repair techniques with the use of cyclic testing is presented. This type of evaluation complements the presently used load-to-failure tests by providing more detailed information about gap formation at the repair site. During load-to-failure testing in this study, core sutures alone demonstrated initial gap formation at 0.85 kg tensile force or more; yet on cyclic testing all techniques demonstrated gap formation of 1.9 mm or greater at 0.5 kg tensile force. Thus cyclic testing demonstrated gap formation not readily apparent on load-to-failure testing. An epitenon stitch placed circumferentially around the laceration site added strength in both load-to-failure and cyclic tests, and significantly reduced gap formation regardless of the core suture technique.

Medical subject headings

Anatomy