ABO-incompatible blood transfusion and invasive therapeutic approaches during pediatric cardiopulmonary bypass.

Aliç, Yasin; Akpek, Elif A; Dönmez, Asli; Ozkan, Süleyman; Perfusionist, Güray Yener; Aslamaci, Sait · Anesth Analg · 2008

case_report · Level V

Where this comes from

Abstract

Human error has been identified as a major source of ABO-incompatible blood transfusion which most often results from blood being given to the wrong patient. We present a case of inadvertent administration of ABO-incompatible blood to a 6-mo-old child who underwent congenital heart surgery and discuss the use of invasive therapeutic approaches. Invasive techniques included total circulatory arrest and large-volume exchange transfusion, along with conventional ultrafiltration and plasmapheresis, which could all be performed rapidly and effectively. The combination of standard pharmacologic therapies and alternative invasive techniques after a massive ABO-incompatible blood transfusion led to a favorable outcome in our patient.