2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial.
rct · Level I
Where this comes from
- Record sourced from PubMed, PMID 18855089.
- Also identified by DOI 10.1007/s11999-008-0540-9 and PMC identifier 2600985.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Metal-on-metal bearing total hip arthroplasty is performed more commonly than in the past. There may be manufacturing differences such as clearance, roughness, metallurgy, and head size that affect performance. In a prospective, randomized trial, we compared 2-year postoperative ion levels for a 28-mm metal-on-polyethylene bearing with 28-mm and 36-mm metal-on-metal bearings. We measured serum, erythrocyte, and urine ion levels. We observed no difference in the ion levels for the 28-mm and 36-mm metal-on-metal bearings. The ion levels in these patients were lower than reported for most other metal-on-metal bearings. Although both erythrocyte and serum cobalt increased, erythrocyte chromium and erythrocyte titanium did not increase despite a four- to sixfold serum chromium and a three- to fourfold serum titanium increase. This may represent a threshold level for serum chromium and serum titanium below which erythrocytes are not affected. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
- Metals
- Polyethylene
Anatomy
- hip