Biomechanic evaluation of upper-extremity symmetry during manual wheelchair propulsion over varied terrain.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 18929029.
- Also identified by DOI 10.1016/j.apmr.2008.03.020 and PMC identifier 3899826.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate upper-extremity symmetry during wheelchair propulsion across multiple terrain surfaces. Case series. A biomechanics laboratory and the general community. Manual wheelchair users (N=12). Not applicable. Symmetry indexes for the propulsion moment, total force, tangential force, fractional effective force, time-to-peak propulsion moment, work, length of push cycle, and power during wheelchair propulsion over outdoor and indoor community conditions, and in laboratory conditions. Upper-extremity asymmetry was present within each condition. There were no differences in the magnitude of asymmetry when comparing laboratory with indoor community conditions. Outdoor community wheelchair propulsion asymmetry was significantly greater than asymmetry measured during laboratory conditions. Investigators should be aware that manual wheelchair propulsion is an asymmetrical act, which may influence interpretation when data is collected from a single limb or averaged for both limbs. The greater asymmetry identified during outdoor versus laboratory conditions emphasizes the need to evaluate wheelchair biomechanics in the user's natural environment.
Medical subject headings
- Functional Laterality
- Movement
- Spinal Cord Injuries
- Upper Extremity
- Wheelchairs