Antegrade retrieval of ureteral stents through an 8-French percutaneous nephrostomy route.

Liang, Huei-Lung; Yang, Tsung-Lung; Huang, Jer-Shyung; Lin, Yih-Huie; Chou, Chen-Pin; Chen, Matt Chiung-Yu; Pan, Huay-Ben · AJR Am J Roentgenol · 2008

retrospective_cohort · Level III

Where this comes from

Abstract

The purpose of this study was to describe the technique of antegrade retrieval of ureteral stents under fluoroscopic guidance through an 8-French nephrostomy. During an 8-year period, we retrieved 26 ureteral stents from 24 patients who were not candidates for retrograde removal or had other conditions precluding use of a retrograde approach. A loop snare or grasping forceps was used to retrieve a ureteral stent in the renal pelvis or calyx or upper ureter through an 8-French vascular sheath with a safety wire in place. A snare catheter advanced into the bladder for retrieval of the bladder end was used in patients in whom retrieval with both a loop snare and a grasping forceps failed. All 26 ureteral stents were successfully retrieved by the antegrade approach. Ten stents were retrieved with a snare alone and nine with a forceps alone. Five stents were retrieved successfully with a forceps after initial failures with snare catheters. Two stents were retrieved with snare catheters advanced into the bladder. The major complication of nephrostomy wound infection occurred in a patient with a urinary tract infection who underwent a one-stage procedure. All minor complications, including pelvic perforation in one patient and blood clot in the renal pelvis in four patients, resolved spontaneously without adverse sequelae. Antegrade percutaneous retrieval of a ureteral stent through an 8-French nephrostomy is safe and effective and has a high degree of technical success. It can be used as a routine interventional practice in radiology.

Medical subject headings