Evaluation of different mixing study reagents and dilution effect in lupus anticoagulant testing.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 1899962.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Until recently, the laboratory identification of lupus anticoagulants (LA) was not considered important. Often LA were regarded as a nuisance, resulting in factor assays and other coagulation tests with inconclusive results. However, the recognition of important clinical complications associated with the presence of LA has resulted in an emphasis on the detection of this phospholipid-dependent inhibitor. Most studies have evaluated the sensitivity of various screening or confirmatory procedures used in establishing the diagnosis of LA. The authors have focused on the variables involved in the mixing studies used to identify the presence of a circulating inhibitor. To detect the latter, attention to the ratio of patient plasma to normal plasma is important, particularly in the case of a minimally prolonged APTT. Also the source of "normal" plasma must be platelet poor to maximize sensitivity in the case of a weak LA.
Medical subject headings
- Blood Coagulation Factors
- Clinical Laboratory Techniques
- Indicators and Reagents