Preventing parastomal hernia with a prosthetic mesh: a 5-year follow-up of a randomized study.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 19011935.
- Also identified by DOI 10.1007/s00268-008-9785-4.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Parastomal hernia is a major clinical problem. In a randomized, clinical trial, a prosthetic mesh in a sublay position at the index operation reduced the rate of parastomal hernia at 12-month follow-up, without any increase in the rate of complications. This study was designed to evaluate the rate of complications after 5 years. Between January 2001 and April 2003, 54 patients who had a permanent ostomy were randomized to a conventional stoma or to a stoma with the addition of a mesh in a sublay position. A large-pore, lightweight mesh with a reduced polypropylene content and a high proportion of absorbable material was used. After 5 years, 21 patients with a conventional stoma were alive and parastomal herniation was recorded in 17 patients, of whom repair had been demanded in 5. In 15 patients operated on with the addition of a mesh herniation, that did not require repair, was present in 2 (P<0.001). No fistulas or strictures developed. No mesh infection was noted and no mesh was removed during the study period. At stoma formation, a prophylactic low-weight mesh in a sublay position is a safe procedure that reduces the rate of parastomal hernia.
Medical subject headings
- Colostomy
- Hernia, Ventral
- Postoperative Complications
- Surgical Mesh
- Surgical Stomas