Aortic valve replacement for aortic stenosis during orthotopic cardiac transplant.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 19022027.
- Also identified by DOI 10.1016/j.athoracsur.2008.04.097.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Although concomitant coronary bypass, and mitral and tricuspid valve surgery have been used to expand the donor pool for cardiac transplantation, aortic valve disease is considered an absolute contraindication for use of an offered organ. A case is presented with the successful use of an organ requiring concomitant aortic valve replacement for calcific aortic stenosis on a congenitally bicuspid valve. Eighteen-month follow-up documented excellent allograft function with a normally functioning mechanical aortic prosthesis. Aortic valve disease in offered organs can be successfully treated with aortic valve replacement at the time of transplantation and should not preclude the use of the organ in the setting of a recipient who is a candidate for a marginal allograft.
Medical subject headings
- Aortic Valve Stenosis
- Bioprosthesis
- Heart Transplantation
- Heart Valve Prosthesis Implantation
- Tissue Donors