An improved method for cable grip fixation of the greater trochanter after trochanteric slide osteotomy.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 19062247.
- Also identified by DOI 10.1016/j.arth.2008.10.006 and PMC identifier 5555050.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study proposes a novel method for reattachment of the trochanteric slide osteotomy. The strength of this new fixation system was compared to established configurations. Fifteen sawbone femurs were used. Our configuration used cables above and below the lesser trochanter with a third cable around the shaft of the femur while passing the loose ends through the inferior hole of the cable grip. Displacement of the trochanter was measured with increasing load. Force required for catastrophic failure was also measured. The 3-cable construct resulted in significantly less displacement with increasing load and required a larger force to cause failure (1 cm and 2 cm). We theorize that our configuration produces a biomechanically stronger construct than previously used methods.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Femur
- Osteotomy
Anatomy
- femur
- hip