Comparison of single- and double-bundle anterior cruciate ligament reconstruction using quadriceps tendon-bone autografts.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 19111221.
- Also identified by DOI 10.1016/j.arthro.2008.09.004.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to evaluate and compare postoperative knee stability and functional scores between single- and double- bundle anterior cruciate ligament (ACL) reconstruction with the use of quadriceps tendon-bone autografts at a 2-year follow-up. The records of 59 patients who had ACL reconstruction between January 2005 and April 2006 were analyzed retrospectively. Twenty-eight patients had single-bundle reconstruction (group S) and 31 received double-bundle reconstruction (group D). Ligament stability was assessed with the Lachman and pivot-shift tests and a KT-2000 arthrometer. International Knee Documentation Committee (IKDC) and Lysholm scores were employed to evaluate the functional outcomes. The postoperative mean side-to-side difference for group S was 2.64 mm and 1.79 mm for group D, a difference that was found to be statistically significant (P = .020). Regarding the pivot-shift test, 3 patients had grade 1+ and 1 patient had grade 2+ pivot-shift in group S, while no patients had abnormal pivot-shift in group D (P = .093). The patients who reported grade A or B on IKDC scores were 24 and 28 in group S and D, respectively (P > .1). On the questionnaire of the twisting activity, although statistical difference was not found between the groups, there was a trend toward more restriction in twisting activity in group S (P = .096). We found significant correlation between the twisting activity and instability questionnaire of the Lysholm score (Spearman coefficient, 0.737; P < .001). Double-bundle ACL reconstruction using quadriceps tendon-bone autografts provide less laxity (1.79 mm) than single-bundle ACL reconstruction (2.64 mm) as measured by the KT-2000. However, we could not find any significant differences in the functional measurements between the 2 groups. Level III, retrospective comparative study.
Medical subject headings
- Anterior Cruciate Ligament
- Femur
- Knee Injuries
- Orthopedic Procedures
- Quadriceps Muscle
- Plastic Surgery Procedures
- Tendons
Anatomy
- knee
- femur