Biomechanical comparison of traditional and minimally invasive intradural tumor exposures using finite element analysis.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 19121823.
- Also identified by DOI 10.1016/j.clinbiomech.2008.11.005.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Minimally invasive approaches to intradural pathology have evolved in part in an effort to reduce approach related destabilization of the spine. No biomechanical data exist however evaluating the effects of traditional and minimally invasive exposures. A finite element model of the lumbar spine was generated, and a simulated open laminectomy and a modified hemilaminectomy at L4 were performed. Forces were applied to assess changes in flexion, extension, axial rotation, and lateral bending. Open laminectomy produced much greater changes in extension, flexion, and axial rotation than the modified hemilaminectomy from the intact. Lateral bending was similarly unaffected for both exposures. The results suggest that a minimally invasive hemilaminar exposure preserves the structural integrity of the lumbar spine and minimizes alterations to segmental motion postoperatively.
Medical subject headings
- Carcinoma in Situ
- Laminectomy
- Lumbar Vertebrae
- Minimally Invasive Surgical Procedures
- Models, Biological
Anatomy
- lumbar spine