Optimal use of Myco/F lytic and standard BACTEC blood culture bottles for detection of yeast and mycobacteria.

Kirby, James E; Delaney, Meghan; Qian, Qinfang; Gold, Howard S · Arch Pathol Lab Med · 2009

retrospective_cohort · Level III

Where this comes from

Abstract

The optimal use of dedicated fungal and mycobacterial blood culture bottles, such as the BACTEC Myco/F Lytic bottle, has not been well defined in clinical practice. To compare the performance of Myco/F Lytic and standard blood culture in clinical practice in an urban tertiary care hospital setting and to implement a strategy for optimal use of Myco/F Lytic culture. Retrospective review of laboratory records. Myco/F Lytic culture did not increase detection of yeasts. Nor did it decrease time to detection except for Candida glabrata, where mean time to positivity dropped from 2.6 +/- 1.1 days in standard to 1.8 +/- 0.8 days in Myco/F Lytic culture. Therefore, an algorithm was developed in which Myco/F Lytic culture was reserved primarily for detection of mycobacteria in patients with severely depressed CD4 counts. Implementation of this algorithm led to a sustained 3-fold reduction in Myco/F Lytic blood culture usage. Retrospective analysis suggests substantial clinical equivalence of standard blood and Myco/F Lytic culture for detection of yeast. A multifaceted educational approach based on this data led to a sustained change in physician ordering practices and more cost-effective use of resources.

Medical subject headings