The proximal hip joint capsule and the zona orbicularis contribute to hip joint stability in distraction.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 19148941.
- Also identified by DOI 10.1002/jor.20852.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The structure and function of the proximal hip joint capsule and the zona orbicularis are poorly understood. We hypothesized that the zona orbicularis is an important contributor to hip stability in distraction. In seven cadaveric hip specimens from seven male donors we distracted the femur from the acetabulum in a direction parallel to the femoral shaft with the hip in the neutral position. Eight sequential conditions were assessed: (1) intact specimen (muscle and skin removed), (2) capsule vented, (3) incised iliofemoral ligament, (4) circumferentially incised capsule, (5) partially resected capsule (distal to the zona orbicularis), (6) completely resected capsule, (7) radially incised labrum, and (8) completely resected labrum. The reduction of the distraction load was greatest between the partially resected capsule phase and completely resected capsule phase at 1, 3, and 5 mm joint distraction (p = 0.018). The proximal to middle part of the capsule, which includes the zona orbicularis, appears grossly and biomechanically to act as a locking ring wrapping around the neck of the femur and is a key structure for hip stability in distraction.
Medical subject headings
- Hip Joint
- Joint Capsule
- Joint Instability
Anatomy
- femur
- hip