Orthogonal pin construct versus parallel uniplanar pin constructs for pelvic external fixation: a biomechanical assessment of stiffness and strength.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 19169101.
- Also identified by DOI 10.1097/BOT.0b013e3181962e0e.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study is to compare the structural stiffness of an orthogonal pelvic external fixator pin construct with 2 different parallel external fixator pin constructs in a simulated bone model. An orthogonal pelvic external fixator pin construct would be significantly more stiff than a parallel pin construct when loaded in-plane under similar conditions. Thirty synthetic pelvic bone models were configured with orthogonal pins (group 1), parallel iliac crest pins (group 2), or parallel supra-acetabular pins (group 3). Specimens were loaded either in-plane (flexion/extension moment) or out-of-plane (internal/external rotation moment) to assess construct stiffness. Orthopaedic industry mechanical testing laboratory (Stryker Orthopedics, Mahwah, NJ). Single load cycle to failure with load application modified to assess stiffness both in-plane and out-of-plane with the pin constructs. Pelvic external fixation pin construct stiffness. Stiffness for in-plane loading was 150.2 +/- 51.2 N/mm for the orthogonal pin construct, 105.0 +/- 46.9 N/mm for the iliac crest pin construct, and 104.7 +/- 20.7 N/mm for the supra-acetabular pin construct. Pairwise comparisons demonstrated that the difference was significant (P < 0.05) between groups 1 and 2 and groups 1 and 3 but not between groups 2 and 3. Stiffness for out-of-plane loading was 49.6 +/- 3.4 N/mm for the orthogonal pin construct, 53.9 +/- 3.5 N/mm for the iliac crest pin construct, and 100.6 +/- 4.3 N/mm for the supra-acetabular pin construct, with significant differences (P < 0.05) between groups 1 and 3 and groups 2 and 3 but not between groups 1 and 2. An orthogonal pelvic external fixator pin construct produced a significantly stiffer construct for in-plane loading (flexion/extension moment) compared with either parallel pin construct; however, a parallel supra-acetabular pin construct was stiffer for out-of-plane loading.
Medical subject headings
- Bone Nails
- Compressive Strength
- External Fixators
- Fractures, Bone
- Pelvic Bones
- Pliability
Anatomy
- pelvis