Micropumps operated by swelling and shrinking of temperature-sensitive hydrogels.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 19190798.
- Also identified by DOI 10.1039/b810256b.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This paper describes two types of polymeric micropumps based on the temperature-sensitive hydrogel poly(N-isopropylacrylamide). The gel actuators are realised as photopolymerised patterns and microgels. They are electrothermically controlled by resistive heating elements. The diffusion-based micropump contains a photopatterned monolithic actuator, which is placed within the pump chamber, and provides a valveless single layer set-up. The diffusion micropump is intended for low performance applications and can operate in two modes: peristaltic or pulsatile. The maximum operating parameters are a flow rate of 2.8 +/- 0.35 microl min(-1) and a back pressure of 1.28 kPa. The second type, a displacement pump, provides a higher performance (maximal 4.5 microl min(-1) and 15 kPa). The pump comprises a microgel-based actuator, which is placed within a separate actuator layer, and active microvalves. The specific features of the design and performance of the pumps are discussed.