Assessment of accuracy and reliability in preoperative templating for hip resurfacing arthroplasty.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 19251390.
- Also identified by DOI 10.1016/j.arth.2009.01.022.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The current study investigated the accuracy and reliability of hip resurfacing component selection based on digital preoperative templating. Four surgeons made a template of preoperative radiographs on 2 occasions for acetabular and femoral components in 50 randomly selected hip resurfacing patients. Component selection reliability was variable among surgeons (kappa = 0.16-0.73) and fair between surgeons (kappa = 0.23-0.32). The average percentage of agreement for the acetabular component was 47% (range, 32%-64%) and for the femoral component was 54% (range, 38%-70%). Surgeons tended to underestimate implant size if the correct implant was not chosen (acetabular, 29%; femoral, 32%). Selection of an undersized femoral component may lead to femoral neck notching or varus implant alignment. This study emphasizes the need for intraoperative verification of preoperative templating results to ensure optimal implant selection in hip resurfacing.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Joint
- Hip Prosthesis
- Osteoarthritis, Hip
- Preoperative Care
- Prosthesis Design
Anatomy
- femur
- hip