Acetabular revision with impacted morselized cancellous bone graft and a cemented cup in patients with rheumatoid arthritis. A concise follow-up, at eight to nineteen years, of a previous report.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 19255226.
- Also identified by DOI 10.2106/JBJS.G.01701.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We previously reported our results at a minimum of three years after thirty-five revisions of total hip arthroplasty acetabular components in twenty-eight patients with rheumatoid arthritis. The revisions were performed with use of impacted morselized bone graft and a cemented cup. This update report presents the results at eight to nineteen years after the surgery, which, to our knowledge, is the longest follow-up available in the literature. No patient was lost to follow-up. Since our previous report, there were two additional cup failures due to aseptic loosening, at ten and sixteen years postoperatively. Kaplan-Meier analysis showed the probability of survival of the acetabular component at twelve years to be 80% (95% confidence interval, 65% to 95%) with removal of the cup for any reason as the end point and 85% (95% confidence interval, 71% to 99%) with aseptic loosening as the end point. Cup revisions performed with cement and use of impaction bone-grafting in patients with rheumatoid arthritis led to acceptable long-term prosthetic survival rates. This technique is attractive from a biological standpoint because of the possibility of maintaining acetabular bone stock.
Medical subject headings
- Acetabulum
- Arthritis, Rheumatoid
- Arthroplasty, Replacement, Hip
- Bone Transplantation
Anatomy
- hip
- pelvis