Reproducibility of RTVue retinal nerve fiber layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 19268891.
- Also identified by DOI 10.1016/j.ajo.2008.12.032 and PMC identifier 3465966.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate RTVue spectral-domain optical coherence tomography (OCT) (Optovue Inc, Fremont, California, USA) reproducibility and to assess agreement with Stratus time-domain OCT (Carl Zeiss Meditec, Dublin, California, USA) measurements. Observational clinical study. Scans were obtained from both eyes of all participants 3 times using the RTVue nerve head map 4-mm diameter protocol and once using Stratus OCT within the same session. RTVue reproducibility and agreement with Stratus OCT were evaluated for retinal nerve fiber layer (RNFL) and optic disc measurements. Thirty healthy participants (60 eyes) and 38 glaucoma patients (76 eyes) were included in the study. RTVue reproducibility was good in both healthy participants and patients. For average RNFL thickness, the intraclass correlation coefficients in healthy eyes and patient eyes were 0.97 whereas for rim area they were 0.97 and 0.96, respectively. The correlation between RTVue and Stratus measurements generally was good, especially for average RNFL thickness (healthy eyes and patient eyes, r(2) = 0.82 and 0.86, respectively) and rim volume (healthy eyes and patient eyes, r(2) = 0.78 and 0.76, respectively). Bland-Altman plots showed good agreement between the instruments, with better agreement for average RNFL thickness (95% limits of agreement in healthy eyes and patient eyes, -8.6 to 12 microm and -5.6 to -14.8 microm, respectively) than optic disc parameters. Cup-to-disc ratio 95% limits of agreement in healthy eyes and patient eyes were -0.3 to 0.4 and -0.2 to 0.3, respectively. Optic disc measurements with RTVue were smaller than those with Stratus OCT (eg, disc area was on average 0.4 mm(2) smaller and rim area was 0.3 mm(2) smaller with RTVue). Reproducibility of RTVue RNFL and optic disc measurements was excellent in both groups. The level of agreement between RTVue and Stratus measurements suggests that RTVue has the potential to detect glaucomatous structural changes.
Medical subject headings
- Diagnostic Techniques, Ophthalmological
- Glaucoma, Open-Angle
- Nerve Fibers
- Optic Disk
- Optic Nerve Diseases
- Retinal Ganglion Cells
- Tomography, Optical Coherence