Experimental comparison of lesion detectability for four fully-3D PET reconstruction schemes.
other
Where this comes from
- Record sourced from PubMed, PMID 19272998.
- Also identified by DOI 10.1109/TMI.2008.2006520 and PMC identifier 2798572.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The objective of this work was to evaluate the lesion detection performance of four fully-3D positron emission tomography (PET) reconstruction schemes using experimentally acquired data. A multi-compartment anthropomorphic phantom was set up to mimic whole-body (18)F-fluorodeoxyglucose (FDG) cancer imaging and scanned 12 times in 3D mode, obtaining count levels typical of noisy clinical scans. Eight of the scans had 26 (68)Ge "shell-less" lesions (6, 8-, 10-, 12-, 16-mm diameter) placed throughout the phantom with various target:background ratios. This provided lesion-present and lesion-absent datasets with known truth appropriate for evaluating lesion detectability by localization receiver operating characteristic (LROC) methods. Four reconstruction schemes were studied: 1) Fourier rebinning (FORE) followed by 2D attenuation-weighted ordered-subsets expectation-maximization, 2) fully-3D AW-OSEM, 3) fully-3D ordinary-Poisson line-of-response (LOR-)OSEM; and 4) fully-3D LOR-OSEM with an accurate point-spread function (PSF) model. Two forms of LROC analysis were performed. First, a channelized nonprewhitened (CNPW) observer was used to optimize processing parameters (number of iterations, post-reconstruction filter) for the human observer study. Human observers then rated each image and selected the most-likely lesion location. The area under the LROC curve ( A(LROC)) and the probability of correct localization were used as figures-of-merit. The results of the human observer study found no statistically significant difference between FORE and AW-OSEM3D ( A(LROC)=0.41 and 0.36, respectively), an increase in lesion detection performance for LOR-OSEM3D ( A(LROC)=0.45, p=0.076), and additional improvement with the use of the PSF model ( A(LROC)=0.55, p=0.024). The numerical CNPW observer provided the same rankings among algorithms, but obtained different values of A(LROC). These results show improved lesion detection performance for the reconstruction algorithms with more sophisticated statistical and imaging models as compared to the previous-generation algorithms.
Medical subject headings
- Image Processing, Computer-Assisted
- Neoplasms
- Positron-Emission Tomography
- Whole Body Imaging