Flexor tendon repair in zone 2 using a six-strand 'figure of eight' suture.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 19282406.
- Also identified by DOI 10.1177/1753193408099818.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The tensile strength of three different flexor tendon repair techniques were tested in vitro: the modified Kessler technique (a two-strand repair), two 'figure of eight' sutures (a four-strand repair) and three 'figure of eight' sutures (a six-strand repair). The mean breaking forces for the three techniques were 48.0 N, 73.1 N and 93.3 N, respectively, and the differences were highly significant (p < 0.0001). In a prospective clinical study, a total of 45 patients (50 fingers) with clean-cut complete lacerations of both flexor tendons in zone 2 were included. The protocol used the three 'figure of eight' suture techniques for (profundus only) tendon repair, 'venting' of the pulleys, and post-operative immediate active range of motion that ensured full active extension of the proximal interphalangeal joint. One repair (2%) ruptured. In the remaining 49 repairs, the result was considered excellent in 39 (78%) and good in 10 (20%) using the Strickland and Glogovac grading system.
Medical subject headings
- Finger Injuries
- Orthopedic Procedures
- Suture Techniques
- Tendon Injuries
- Tendons