Flexor tendon problems after volar plate fixation of distal radius fractures.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 19283432.
- Also identified by DOI 10.1007/s11552-009-9180-0 and PMC identifier 2787213.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Four cases of flexor tendon problems which developed after volar plate fixation of distal radius fractures are presented. All cases were associated with close contact of the screws or distal edge of the plate with the flexor tendons. Poor bone stock or multiple bone fragments allowing loosening of the plate or non-locking screws cause the hardware to irritate the flexor tendons and ultimately lead to rupture. The flexor tendons involved include the flexor carpi radialis, flexor pollicis longus and flexor digitorum superficialis, and flexor digitorum profundus to the index and long fingers.
Anatomy
- radius