The use of 99mTc-recombinant human annexin V imaging for differential diagnosis of aseptic loosening and low-grade infection in hip and knee prostheses.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 19289427.
- Also identified by DOI 10.2967/jnumed.108.059345.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to assess the pattern of annexin V uptake in hip and knee prostheses suspected of being infected. A total of 7 patients undergoing revision surgery for hip or knee prostheses were studied; 5 patients had total hip replacements, and 2 had total knee replacements. Infection was confirmed by pathology, culture results, laboratory evaluation, and clinical follow-up. All patients also underwent a bone scan before surgery. Annexin V scan findings were positive in 5 patients and negative in 2. Annexin V uptake was either focal (n = 4) or linear (n = 1). There were 4 true-positive, 2 true-negative, 1 false-positive, and no false-negative annexin V studies. Annexin V uptake was either more extensive or less extensive than, and usually was incongruent with, (99m)Tc-methylene diphosphonate uptake. Our findings suggest that annexin V imaging shows greater uptake with infection than with aseptic loosening and has a high negative predictive value for prosthetic infection.
Medical subject headings
- Annexin A5
- Bacterial Infections
- Hip Prosthesis
- Joint Instability
- Knee Prosthesis
- Organotechnetium Compounds
- Prosthesis Failure
- Prosthesis-Related Infections