Rodless end-loop stomas. Seven-year experience.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 1935478.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The rodless, end-loop stoma was developed as an alternative to the more traditional loop stoma to minimize patient management problems. A retrospective review of our seven-year experience in 229 patients with end-loop colostomies (135), ileocolostomies (70), and ileostomies (24) is presented. A total of 30 stoma-related complications were observed in 27 stomas, for an overall complication rate of 13.1 percent. The most common complications were skin excoriation secondary to leakage (3.5 percent), retraction (3.5 percent), partial necrosis (2.6 percent), and peristomal sepsis (1.8 percent). Mucocutaneous separation, prolapse, and stenosis were each seen in less than one percent of patients. No cases of stomal herniation, obstruction, or hemorrhage were encountered. Twelve deaths occurred, but none was attributed to stoma-related complications. The rodless, end-loop stoma is a simple and safe procedure with many advantages and a low incidence of complications.
Medical subject headings
- Colostomy
- Ileostomy