Early dose response to yttrium-90 microsphere treatment of metastatic liver cancer by a patient-specific method using single photon emission computed tomography and positron emission tomography.

Campbell, Janice M; Wong, C Oliver; Muzik, Otto; Marples, Brian; Joiner, Michael; Burmeister, Jay · Int J Radiat Oncol Biol Phys · 2009

retrospective_cohort · Level III

Where this comes from

Abstract

To evaluate a patient-specific single photon emission computed tomography (SPECT)-based method of dose calculation for treatment planning of yttrium-90 ((90)Y) microsphere selective internal radiotherapy (SIRT). Fourteen consecutive (90)Y SIRTs for colorectal liver metastasis were retrospectively analyzed. Absorbed dose to tumor and normal liver tissue was calculated by partition methods with two different tumor/normal liver vascularity ratios: an average 3:1 and a patient-specific ratio derived from pretreatment technetium-99m macroaggregated albumin SPECT. Tumor response was quantitatively evaluated from fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography scans. Positron emission tomography showed a significant decrease in total tumor standardized uptake value (average, 52%). There was a significant difference in the tumor absorbed dose between the average and specific methods (p = 0.009). Response vs. dose curves fit by linear and linear-quadratic modeling showed similar results. Linear fit r values increased for all tumor response parameters with the specific method (+0.20 for mean standardized uptake value). Tumor dose calculated with the patient-specific method was more predictive of response in liver-directed (90)Y SIRT.

Medical subject headings