Reference values for continuous glucose monitoring in Chinese subjects.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 19389816.
- Also identified by DOI 10.2337/dc09-0076 and PMC identifier 2699703.
- Licence recorded as CC BY-NC-ND.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The widespread clinical application of continuous glucose monitoring (CGM) is limited by the lack of generally accepted reference values. This multicenter study aims to establish preliminary normal reference values for CGM parameters in a sample of healthy Chinese subjects. A total of 434 healthy individuals with normal glucose regulation completed a 3-day period of glucose monitoring using a CGM system. The 24-h mean blood glucose (24-h MBG) and the percentage of time that subjects' blood glucose levels were >or=140 mg/dl (PT140) and <or=70 mg/dl (PT70) within 24 h were analyzed. There was excellent compliance of finger stick blood glucose values with CGM measurements for subjects. Among the 434 subjects, the daily blood glucose varied from 76.9 +/- 11.3 to 144.2 +/- 23.2 mg/dl. The 24-h MBG, PT140, and PT70 were 104 +/- 10 mg/dl, 4.1 +/- 5.8%, and 2.4 +/- 5.3%, respectively. As for these parameters, no significant differences were found between men and women. The 95th percentile values were adopted as the upper limits of CGM parameters, which revealed 119 mg/dl (6.6 mmol/l) for 24-h MBG, 17.1% for PT140, and 11.7% for PT70. We recommend a 24-h MBG value <119 mg/dl, PT140 <17% (4 h), and PT70 <12% (3 h) as normal ranges for the Chinese population.
Medical subject headings
- Blood Glucose
- Monitoring, Ambulatory