Test-retest reliability of drug-induced sleep endoscopy.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 19393404.
- Also identified by DOI 10.1016/j.otohns.2009.01.012 and PMC identifier 2845469.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To determine the test-retest reliability of drug-induced sleep endoscopy (DISE). Prospective cohort study. Patients with OSA underwent two separate DISE examinations. The following outcomes were measured: a global assessment of obstruction at the palate and/or hypopharynx; the degree of obstruction at the palate and hypopharynx; and the contribution of individual structures (palate, tonsils, tongue, epiglottis, and lateral pharyngeal walls) to obstruction. Thirty-two patients underwent two separate DISE examinations. The preoperative sleep study apnea-hypopnea index was 40.7 +/- 21.1, and the lowest oxygen saturation was 79.8 +/- 17.4 percent. Point estimates for the intraclass correlation coefficient analogs related to palatal obstruction ranged from 0.41 to 0.89; related to the hypopharyngeal airway, the point estimates ranged from 0.57 to 0.84. The test-retest reliability of DISE appears good, especially in the evaluation of the hypopharyngeal airway. Larger studies can generate more precise confidence interval estimates and test the generalizability of these findings.
Medical subject headings
- Anesthetics, Intravenous
- Endoscopy
- Propofol
- Sleep Apnea, Obstructive