Fixation of the proximal interphalangeal arthrodesis with the use of an intraosseous loop of stainless-steel wire suture.

Harris, William; Mote, Gregory A; Malay, D Scot · J Foot Ankle Surg · 2009

case_report · Level V

Where this comes from

Abstract

A wide range of options is available to surgeons for fixation of the proximal interphalangeal joint when arthrodesis is undertaken for repair of the hammertoe deformity. In this technical report, we describe the use of an intraosseous loop of stainless-steel wire for permanent stabilization of the interface between the proximal and middle phalanges during fusion of the interphalangeal joint.

Medical subject headings