Variability of somatosensory cortical evoked potentials during spinal surgery. Effects of anesthetic technique and high-pass digital filtering.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 1948378.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The effects of anesthetic technique (nitrous oxide or propofol) and high-pass digital filtering on within-patient variability of posterior tibial nerve somatosensory cortical evoked potentials (PTN-SCEP) were compared prospectively in two groups of 20 patients undergoing spinal surgery. Average P1N1 amplitude was significantly higher and P1N1 amplitude variability lower during propofol/alfentanil anesthesia than during nitrous oxide/alfentanil anesthesia. Off-line 30-Hz high-pass digital filtering significantly reduced P1N1 amplitude variability without decreasing P1N1 amplitude. In 93 patients studied retrospectively, a significant negative logarithmic correlation (r = -0.77) was observed between P1N1 amplitude and P1N1 amplitude variability. This study shows the importance of maintaining the highest possible PTN-SCEP amplitudes during spinal surgery. Propofol/opioid anesthesia may be an alternative anesthetic technique to nitrous oxide/opioid anesthesia during spinal cord function monitoring.
Medical subject headings
- Anesthesia, General
- Evoked Potentials, Somatosensory
- Monitoring, Intraoperative
- Signal Processing, Computer-Assisted
- Spine