Primitive results after medial-pivot knee arthroplasties: a minimum 5-year follow-up study.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 19577880.
- Also identified by DOI 10.1016/j.arth.2009.05.008.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Paradoxical anterior movement of the femoral condyles after total knee arthroplasty (TKA) often attenuates the extension mechanism and causes a suboptimal outcome. The medial-pivot implant design aimed to confine anterior movement and emulate physiologic knee kinematics. In our study, a consecutive series of 58 medial-pivot TKA were enrolled with a minimum 5-year follow-up. The Knee Society score improved from 30.5 to 91.1 in objective and from 36.7 to 82.3 in functional scale. The average range of motion was 115.4 degrees . The medial-pivot TKA provided significant improvement in the postoperative range of motion, objective Knee Society score, pain scale, and functional score (P < .05) statistically. A larger sample and longer follow-up are recommended to draw definitive conclusions of this new implant design.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Knee Joint
- Knee Prosthesis
- Osteoarthritis, Knee
- Range of Motion, Articular
Anatomy
- knee