Diagnostic ability of Fourier-domain vs time-domain optical coherence tomography for glaucoma detection.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 19589493.
- Also identified by DOI 10.1016/j.ajo.2009.05.030 and PMC identifier 2784699.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To compare retinal nerve fiber layer (RNFL) thickness assessments and the discriminating ability of Fourier-domain optical coherence tomography (FD-OCT) with that of time-domain optical coherence tomography (TD-OCT) for glaucoma detection. Prospective, nonrandomized, observational cohort study. Normal and glaucomatous eyes underwent complete examination, standard automated perimetry, optic disc photography, TD-OCT (Stratus OCT; Carl Zeiss Meditec, Dublin, California, USA), and FD-OCT (RTVue; Optovue Inc, Fremont, California, USA). One eye per subject was enrolled. Two consecutive scans were acquired using a 3.46-mm diameter scan with TD-OCT and a 3.45-mm diameter scan with FD-OCT. For each of 5 RNFL parameters, the area under the receiver operator characteristic curve was calculated to compare the ability of FD-OCT and TD-OCT to discriminate between normal and glaucomatous eyes. Fifty healthy persons (mean age, 65.3 +/- 9.9 years) and 50 glaucoma patients (mean age, 67.7 +/- 10.5 years) were enrolled. Average, superior, and inferior RNFL thickness measurements (in micrometers) were significantly (P < .01) greater with FD-OCT compared with TD-OCT in normal eyes (103.3 +/- 12.6 vs 96.3 +/- 10.7, 134.5 +/- 18.6 vs 113.9 +/- 16.3, and 129.7 +/- 16.9 vs 125.5 +/- 15.8, respectively) and glaucomatous eyes (P < .001; 77.6 +/- 17.6 vs 70.4 +/- 18.6, 108.0 +/- 26.8 vs 86.8 +/- 30.2, 82.2 +/- 3.3 vs 73.5 +/- 26.1, respectively). The area under the receiver operator characteristic curves for RNFL thickness were similar (P > .05) using FD-OCT (average, 0.88; superior, 0.80; inferior, 0.94) and TD-OCT (average, 0.87; superior, 0.79; inferior, 0.95). Cross-sectional peripapillary RNFL thickness measurements obtained using FD-OCT generated with the RTVue are greater than those obtained with TD-OCT and have similar diagnostic performance for glaucoma detection.
Medical subject headings
- Diagnostic Techniques, Ophthalmological
- Glaucoma
- Nerve Fibers
- Optic Disk
- Optic Nerve Diseases
- Retinal Ganglion Cells
- Tomography, Optical Coherence