The effect of material model formulation in the stress analysis of abdominal aortic aneurysms.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 19657744.
- Also identified by DOI 10.1007/s10439-009-9767-1 and PMC identifier 2822466.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A reliable estimation of wall stress in Abdominal Aortic Aneurysms (AAAs), requires performing an accurate three-dimensional reconstruction of the medical image-based native geometry and modeling an appropriate constitutive law for the aneurysmal tissue material characterization. A recent study on the biaxial mechanical behavior of human AAA tissue specimens demonstrates that aneurysmal tissue behaves mechanically anisotropic. Results shown in this communication show that the peak wall stress is highly sensitive to the anisotropic model used for the stress analysis. In addition, the present investigation indicates that structural parameters (e.g., collagen fiber orientation) should be determined independently and not by means of non-linear fitting to stress-strain test data. Fiber orientation identified in this manner could lead to overestimated peak wall stresses.
Medical subject headings
- Aorta, Abdominal
- Aortic Aneurysm, Abdominal
- Blood Flow Velocity
- Blood Pressure
- Models, Cardiovascular