The impact of intra-operative transoesophageal echocardiography on cardiac surgical practice.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 19686478.
- Also identified by DOI 10.1111/j.1365-2044.2009.05991.x.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The use of transoesophageal echocardiography during cardiac surgery has increased dramatically and it is now widely accepted as a routine monitoring and diagnostic tool. A prospective study was carried out between September 2004 and September 2007, and included all patients in whom intra-operative echocardiography was performed, 2 473 (44%) out of a total of 5 591 cases. Changes to surgery were subdivided into predictable (where echocardiographic examination was planned specifically to guide surgery) and unpredictable (new pathology not diagnosed pre-operatively). A change in the planned surgical procedure was documented in 312 (15%) cases. In 216 (69%) patients the changes were predictable and in 96 (31%) they were unpredictable. The number of predictable changes increased between 2004-5 and 2006-7 (8% vs 13%, p = 0.025). In these cases, intra-operative echocardiography was specifically requested by the surgeon to help determine the operative intervention. This has implications for consent and operative risk, which have yet to be fully determined.
Medical subject headings
- Cardiac Surgical Procedures
- Echocardiography, Transesophageal
- Monitoring, Intraoperative