The effects of human amniotic membrane and periosteal autograft on tendon healing: experimental study in rabbits.

Ozbölük, S; Ozkan, Y; Oztürk, A; Gül, N; Ozdemir, R M; Yanik, K · J Hand Surg Eur Vol · 2010

basic_science · Level V

Where this comes from

Abstract

In this study, the effects of periosteal autograft and human amniotic membrane on tendon healing were compared. Forty-two New Zealand rabbits were divided into three groups. Flexor digitorum fibularis tendons were cut and repaired with a modified Kessler technique and circumferential sutures in all groups. Tendon repair alone was carried out in group 1, tendon repair and application of human amniotic membrane was done in group 2 and tendon repair and application of periosteal autograft was done in group 3. Biomechanical and histopathological examinations were done 2 and 6 weeks postoperatively. Biomechanical examination showed that group 3 was the strongest at weeks 2 and 6. Adhesion, inflammation and new bone formation showed no difference between groups at week 2. However, adhesion formation was found to be less in groups 2 and 3 than group 1 at week 6. The application of periosteal autograft might be useful in repair of tendon injuries.

Medical subject headings

Anatomy