Endobronchial closure of total bronchopleural fistula with Occlutech Figulla ASD N device.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 19699881.
- Also identified by DOI 10.1016/j.athoracsur.2009.06.069.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Bronchopleural fistula may be treated by medical, endoscopic, and surgical techniques, but large fistulas remain a challenge to be closed using endoscopic techniques. We describe the endoscopic closure of a bronchial total fistula with the Occlutech Figulla ASD N device (International Occlutech AB, Helsingborg, Sweden), originally designed for closure of an atrial septal defect. The procedure was conducted without general anesthesia or rigid bronchoscopy, bronchography, or radioscopy. An immediate reduction in the air leak was observed and also later on bronchoscopy, as the device was almost covered by granulation tissue. The endobronchial technique described seems to be safe and effective to manage large bronchopleural fistulas.
Medical subject headings
- Bronchial Fistula
- Bronchoscopy
- Fistula
- Pleural Diseases
- Postoperative Complications
- Prostheses and Implants
- Prosthesis Implantation