Reoperative surgical stabilization of a painful nonunited rib fracture using bone grafting and a metal plate.

Cho, Yang Hyun; Kim, Hyun Koo; Kang, Du-Young; Choi, Young Ho · J Orthop Trauma · 2009

case_report · Level V

Where this comes from

Abstract

We report a case of a nonunited sixth rib in a patient with multiple rib fractures who underwent internal fixation using a wire and Judet strut 3 times. During the following 3 years, the patient continued to complain of pain and instability. At surgery, a pseudarthrosis between the ends of the sixth rib was excised. A longitudinal gutter crossing the fracture site was fashioned and splinted with an inlay block of cancellous bone grafted from the iliac crest; stabilization was accomplished with a reconstruction plate and screws. The following 2 years of follow-up demonstrated no instability or pain.

Medical subject headings