Comparison of total knee arthroplasty using computer-assisted navigation versus conventional guiding systems: a prospective study.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 19721145.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To compare knee alignments in total knee arthroplasty (TKA) using computer-assisted navigation versus conventional guiding systems. Five men and 49 women aged 49 to 79 years underwent TKA for primary osteoarthritis of the knee with varus deformity. All valgus knees were associated with inflammatory arthritis and thus excluded. Computer-assisted navigation was used for the first 35 TKAs, whereas conventional extramedullary tibial and intramedullary femoral guiding systems were used for the next 35 TKAs. The mechanical axis, coronal tibial and femoral angles, sagittal tibial and femoral angles in the 2 groups were compared. Sagittal tibial and femoral angles aligned more optimally in TKAs using computer-assisted navigation. In the respective computer-assisted navigation and conventional guiding systems, 33 (94%) and 26 (74%) of the TKAs attained a postoperative mechanical axis of <3 degrees varus/valgus. Computer-assisted navigation gives a more consistent alignment correction and reduces outliers during implant positioning.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Surgery, Computer-Assisted
Anatomy
- knee