Periprosthetic femoral fracture after a well-fixed revision total knee arthroplasty treated with in situ effective lengthening of prosthesis.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 19729275.
- Also identified by DOI 10.1016/j.arth.2009.07.011.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The increasing number of total knee arthroplasties implies a greater likelihood of periprosthetic fractures and need for successful treatment options. We report a case where in situ effective lengthening of the stem of a well-fixed indwelling prosthesis by a custom-made intramedullary nail with taper-lock coupling provided a successful alternative to the established internal fixation techniques involving prosthesis exchange. We believe that effective lengthening of indwelling prosthesis by a custom-made intramedullary nail is an effective option for treating periprosthetic femoral fractures in selected cases, where an attempt of removing well-fixed implant would result in unacceptable bone loss at the joint level.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Femoral Fractures
- Fracture Fixation, Internal
- Knee Prosthesis
- Periprosthetic Fractures
Anatomy
- femur
- knee