Validity and reliability of a computer method to estimate vertebral axial rotation from digital radiographs.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 19820970.
- Also identified by DOI 10.1007/s00586-009-1186-3 and PMC identifier 2899767.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Axial vertebral rotation, an important parameter in the assessment of scoliosis may be identified on X-ray images. In line with the advances in the field of digital radiography, hospitals have been increasingly using this technique. The objective of the present study was to evaluate the reliability of computer-processed rotation measurements obtained from digital radiographs. A software program was therefore developed, which is able to digitally reproduce the methods of Perdriolle and Raimondi and to calculate semi-automatically the rotation degree of vertebra on digital radiographs. Three independent observers estimated vertebral rotation employing both the digital and the traditional manual methods. Compared to the traditional method, the digital assessment showed a 43% smaller error and a stronger correlation. In conclusion, the digital method seems to be reliable and enhance the accuracy and precision of vertebral rotation measurements.
Medical subject headings
- Lumbar Vertebrae
- Radiographic Image Enhancement
- Radiographic Image Interpretation, Computer-Assisted
- Range of Motion, Articular
- Scoliosis
- Thoracic Vertebrae
Anatomy
- lumbar spine
- thoracic spine