Comparison of gating around end-expiration and end-inspiration in radiotherapy for lung cancer.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 19822373.
- Also identified by DOI 10.1016/j.radonc.2009.09.002.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate the advantages and disadvantages of gating around end-expiration and end-inspiration. We created five irradiation protocols to treat 15 patients with lung cancer. They were non-gated irradiation (protocol 1, P1), amplitude-based gating around end-expiration (P2) and end-inspiration (P3), and phase-based gating around end-expiration (P4) and end-inspiration (P5). We compared the lung dosimetric parameters and the treatment time. Compared to P2, in P3 the mean lung dose was reduced by 0.5+/-0.4Gy, V20 by 1.2+/-0.9%, V10 by 1.4+/-0.8%, and V5 by 1.5+/-0.9% (p<0.01). There was no statistically significant difference in these parameters between P4 and P5. At a dose rate of 600 monitor units/min (MUs/min), the average treatment time required for 100MUs was 10, 26, 64, 33, and 33 s, respectively, for P1, P2, P3, P4, and P5. With amplitude-based gating, gating around end-inspiration (P3) produced a greater decrease in the lung dose, however, the treatment time was longest among the four gated protocols. There was no significant difference between the two phase-based gating protocols (P4 and P5) with respect to the radiation dose to the lungs and the treatment time.
Medical subject headings
- Lung Neoplasms
- Respiratory-Gated Imaging Techniques